| About Us > Technical Information |
Proscenium Stage
Please note that a Fire Curtain is in operation in this Venue
Pros. Height: 20ft 1"
Pros. Width: 25ft
Height to Grid: 43ft.
Wings width: 16ft. S/L
Wings width: 15ft 6" S/L
Total Stage width: 56ft 6"
Depth of Stage to Fire Curtain: 19ft 6"
Depth of Stage to Centre of Forestage: 26ft 6"
Prompt Corner Stage Right
With Tech Pro Communication System to Control Room, Fly Floor, rear of
stalls, rear of balcony and intercom to Dressing Rooms.
Stage Dressing
1 set House Tabs (Red)
5 sets of Black Legs
4 Black Borders
1 White Cycloth
1 Black Gauze
Lighting
Strand Pallete VL
96 2.5k dimmers
6 5k dimmers
Additional Information
Distance of LX #4 to Cyc Wall: 3' 6"
Distance of LX #3 to LX #4: 4' 6"
Distance of LX #2 to LX #3: 4' 10"
Distance of LX #1 to LX #2: 4'
Distance of Fire/Iron to LX #1: 2' 11"
Length of LX #l 3 1' 7"
Length of LX #2 31' 6"
Length of LX #3 39' 5"
Length of LX #4 37' 7"
All lighting bars are motorised
There are 10 counter weights flying bars which cannot be moved. These are situated as follows:
#1 upstage of Fire Curtain
#2 upstage of LX1
#2 upstage of LX2
#3 upstage of LX3
#2 upstage of LX4
Listing of Circuit Numbers (Note: all circuits are single - no paired circuits)
FOH: 1 - 30
LX #1: 31 - 44 (l4Cts)
LX #2: 45 - 46 (12Cts)
LX #3: 57 - 68 (l2Cts)
LX #4: (cyc) 98, 99, 100 (3Cts)
Dips
U/S/R: 77, 78, 79,80 (4Cts)
U/S/L: 73, 74, 90, 76 (4 Cts)
D/S/L: 69, 70, 71, 72 (4 Cts)
D/S/R: 81, 82, 83, 84, (4 Cts)
Under Forestage D/S/L -85, 86, 87, 88, 89 (5Cts)
Distance of FOH, LX Bar, from Fire Iron: 35' (approx)
Height of Get-In Door (MacCurtaain Street): 7' 4"
Width of Get-in Door: 6' 6"
Height of Get-in Door (U/S/L): 9' 11"
Width of Get-in Door (U/S/L): 6' 7"
Distance of row: 11'
Lanterns
6 x Source 4 zooms
4 x Source 4 fixed
4 x l.2k Starlette Fersnels
8 x 1.2k Cantata Fersnels
1 x 1k Starlette Fersnels
4 x 1k Harmony Fersnels
20 x 1k Parcans
4 x 1.2k 11/26 Profiles
6 x 1.2k 26/44 Profiles
8 x 1.2k 18/32 Profiles
Teatro Diluvio Cyc Battens (3 separate colour capacity)
NOTE: All lanterns to be rigged must have safety chain attached.
Circuits
F.O.H. (Over Balcony): 30 Circuits
LX BAR 1: 12 Circuts
LX BAR 2: 11 Circuts
LX BAR 3: 12 Circuts
LX BAR 4 (cyc): 3 Circuits
Stage Dips: 22 Circuits
(Limited amount of extension cables available)
Please contact the theatre one week in advance of fit up to confirm availability of Lanterns.
Sound
Studiomaster Showmix 24 channel mixer
Studiomaster 1200D power amplifier
Sony Mini-Disc MDS-JE510
4 Bose 802 Series 11 Speakers (2 in Balcony, 2 in auditorium).
Bose 802C 11 Systems Controller
Limited amount of XLR leads available
Emergency announcement to be played before each performance
Control Room situated at the rear of the Auditorium
Sound Desk situated at the rear of the Auditorium
Dressing Rooms
1 for about 12
1 for about 20
1 for about 4
2 showers and 2 toilets available in dressing room areas
Everyman Palace Theatre Technical Plan 1

Everyman Palace Theatre Technical Plan 2

Notes on Everyman Palace Theatre Technical Plan 2
Flat stage floor, slight undulation. Solid timber with MDF sheeting.
Get-in doors at street level on S/L, with corridor leading to stage.
Ramp from corridor to stage.
Raked auditorium. Pit flat.
10 no flying counterweight bars. WLL, 250kg across bar. 3 Pick-up lines.
Underside of counterweight ladderbars to stage floor distance, when gridded: 12730mm
Length of bars: 10,000mm, with 750mm extension each side available.
Fly floor and loading cradle S/R, access by fixed ladder.
4 no LXPrewired 50mm OD on motorised winch system.
FOH advance bar located above balcony. Single 50 OD tube, 10m long. Access via gantry FOH.
Proscenium height for stage floor: 6085mm. Width 7850mm.
Triangular Moulding on each side of top edge approx 1660mm wide and 2000mm deep.
Restrictions in place re protection of Proscenium and Boxes (listed works).
Contact Details:
Technical Manager - Mark Donovan
Assistant Technical Manager - Brian Mitchel
Tel: 021 450 1673
Fax: 021 450 2820
Email: technicalmanager@everymanpalace.com
House Rules:
For safety reasons all crew working on shows must be experienced, competent crew.
All companies, both national and international, must comply with the law of the land i.e. all current employment and safety legislation etc.
It is essential that the Technical Manager is notified by FAX or Email in advance of arrival at the Theatre regarding details for get-in and technical requirements regarding fit up, rehearsal, crew etc.
A one and a half foot banning order exists on protected parts of the building, e.g. boxes and proscenium arche.
No persons are allowed backstage unless a member of the technical department is in the building and has been notified.
Companies must comply with health and safety statement as well as any requests by the Technical Manager.
The Technical Manager has final say on any health and safety issues regarding stage and auditorium.
Everything that comes in with comapnies must be taken away at the get-out.